- Product Categories
- Friendly Links
Information Name: | Supply Integral Orifice Flowmeter |
Published: | 2013-03-22 |
Validity: | 6000 |
Specifications: | |
Quantity: | 500.00 |
Price Description: | |
Detailed Product Description: | Integral Orifice Flowmeter standard orifice is to measure the flow rate differential pressure generating means, with the flow of the various fluids in the various differential pressure gauge or differential pressure transmitter measurable pipeline. Orifice flowmeter restriction means includes orifice, nozzle, etc. of the ring chamber. Intelligent throttling device (orifice flowmeter) detection function of flow rate, temperature, pressure, and temperature, the the pressure automatically compensate for a new generation of flowmeter, orifice flowmeter using advanced computer technology and micropower new technology, function, compact structure, easy to operate, easy to use. The orifice flowmeter throttling device supporting the use of the differential pressure transmitter, can measure the flow of liquids, steam, gas, the orifice flowmeter widely used in petroleum, chemical, metallurgy, electric power, light industry and other sectors. Pipe full of fluid, when they flow through the pipeline within the throttle device, the stream will be at the throttle member is formed in the throttle device of the local contraction, so that the flow rate increases, the static pressure is low, thus before and after the throttle member will be generated The pressure drop, i.e., differential pressure, the greater the flow of the medium flow, the pressure generated before and after the throttle member, the greater the size of the flow of the fluid, so it can be measured by measuring the differential pressure. This measurement method is based on the basis of the law of conservation of energy and flow continuity law. Intelligent throttling device (flow meter) is the flow rate, temperature, pressure detection function in one, and temperature, the the pressure automatically compensate for a new generation of flowmeter, orifice flowmeter new technology, the use of advanced computer technology and micro-power function, compact, easy to operate, easy to use. Orifice flowmeter, characteristics ▲ throttling device structure is easy to copy, simple, solid, reliable performance, long period of use, low price. Wide range of applications using international standards and processing ▲ ▲ orifice plate calculation, all single-phase flow can be measured, and part of the mixed phase flow can also be applied. ▲ Standard throttling device without real-calibration, can be put into use. ▲ integrated orifice plate installation easier without the pressure tube can be connected directly to the differential pressure transmitter and pressure transmitter. Orifice flowmeter of intelligent features ▲ monocrystalline silicon smart differential pressure sensor ▲ high accuracy, improve self-diagnostic function ▲ smart orifice flowmeter range of its self-programming adjustments. ▲ cumulative flow, instantaneous flow, pressure, temperature can be displayed simultaneously. ▲ online, dynamic full compensation function, but also has a self-diagnosis, self-setting range. ▲ with multiple communication interfaces stability of a wide range of high ▲ ▲ the high precision greater than 10:1 intelligent technical indicators ▲: ± 0.075% ▲ high stability: better than 0.1% FS / year ▲ high static pressure: 40MPa 5 years of continuous work without adjustment ▲ ▲ negligible temperature, static pressure influence the the high overvoltage ▲ anti orifice plate flowmeters Product Selection Model Description DWLG throttling device (Integral Orifice Flowmeter) Code according to their structural characteristics of the two the basic classification K-well plates P nozzle letter nominal pressure (105Pa) 2.5 2.5 10 10 16 16 25 25 64 64 100 100 200 200 Code caliber (mm) 15 1200 15 ~~ 1200mm Code, subdivided according to their structure in the form H standard orifice (donut) Y standard orifice plate (flange) K standard orifice (drill) I the L length ISA 1932 nozzle diameter nozzle Venturi nozzle G W classic venturi S double-well plates Q round segmental orifice Z conical inlet orifice R 1/4 hole plate P the overall eccentric orifice N (built) orifice plate X wedge orifice plate T special throttling device code is not listed above medium 1 liquid 2 gas steam of high temperature liquid code compensation in the form N without pressure, temperature compensation P with pressure compensated output T with temperature compensated output Q with pressure, differential pressure range of micro-differential pressure range of temperature compensation output code transmitter differential pressure range 0 1 low differential pressure range 2 3 high differential pressure range code with live shows W throttling device sensor X smart throttling device (flow meter) |
Admin>>>
You are the 10689 visitor
Copyright © GuangDong ICP No. 10089450, The Huai'an Dwyer Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10689 visitor
Copyright © GuangDong ICP No. 10089450, The Huai'an Dwyer Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility